Grooving Dimension References

  • A and B : Reference dimensions for groove location and groove width.
  • C : Groove diameter after grooving.
  • d : Groove depth.
  • t : Minimum pipe wall thickness.
  • Max. Allowable End OD : Maximum allowable flared outside diameter at the pipe end after grooving.

Grooving Dimensions

Unit : mm

Grooving Dimensions
Nominal Pipe Size
(NPS)
Pipe Outside Dia.
(OD)
A
(mm)
B
(mm)
A·B
Tolerance
Groove Dia. C Groove Depth d
(mm)
Min. Wall t
(mm)
Max. Allowable
End OD (mm)
Dia. (mm) Tolerance
1″33.415.97.1±0.830.2−0.41.61.6536.3
1¼″42.215.97.1±0.839.0−0.41.61.6545.0
1½″48.315.97.1±0.845.1−0.41.61.6551.1
2″60.315.98.7±0.857.2−0.41.61.6563.0
2½″73.015.98.7±0.869.1−0.52.02.1175.7
3″88.915.98.7±0.884.9−0.52.02.1191.4
4″114.315.98.7±0.8110.1−0.52.12.11116.8
5″141.315.98.7±0.8137.0−0.52.12.77143.8
6″168.315.98.7±0.8164.0−0.62.22.77170.9
8″219.119.011.9±0.8214.4−0.62.32.77223.5
10″273.019.011.9±0.8268.3−0.72.43.4277.4
12″323.819.011.9±0.8318.2−0.82.83.96328.2
14″355.623.811.9±0.8350.0−0.82.83.96358.1
16″406.423.811.9±0.8400.8−0.82.84.19408.9
18″457.025.411.9±0.8451.4−0.82.84.19461.3
20″508.025.411.9±0.8502.4−0.82.84.78512.1
22″559.025.412.7±0.8550.2−0.84.44.78563.9
24″610.025.412.7±0.8601.2−0.84.45.54614.7

Extended Groove Depth for Large Diameter Pipe

Unit : mm

Extended Groove Depth for Large Diameter Pipe
Nominal Pipe Size
(NPS)
Pipe Outside Dia.
(OD)
A
(mm)
B
(mm)
A·B
Tolerance
Groove Dia. C Groove Depth d
(mm)
Min. Wall Thickness t
(mm)
Max. Allowable Pipe End
Flare Dia. (mm)
Dia. (mm) Tolerance
8″219.119.111.9±0.8209.0−0.643.72.8220.7
10″273.019.111.9±0.8260.0−0.693.73.4271.6
12″323.819.111.9±0.8310.0−0.764.34.0322.8
14″355.623.811.9±0.8347.0−0.764.34.0358.1
16″406.423.811.9±0.8397.0−0.764.74.2408.9
Reference
For pipe sizes DN 200 and above, refer to the grooving dimensions of the applicable steel pipe and the project specifications.
Cautions
  • Before installation, verify that the groove diameter, groove depth, pipe end condition and flare diameter meet the specified requirements.
  • Grooving dimensions may vary depending on pipe material, wall thickness, equipment settings and working conditions.
  • The values shown are reference dimensions and must be verified against the applicable project criteria before fabrication or installation.